OCT600 SMS Setup

The OCT600 can be setup to report to the portal using the following SMS commands (note the default password of 000000 is used in the examples below):

  • ID{SIM #}#000000 - SIM # is the local SIM card number without local and international code
  • APN;{APN}#000000
  • IP;66.165.183.84;4786#000000
  • TCP1#000000
  • TIMEXXXXX#000000 where XXXXX is the reporting interval desired in increments of 10 seconds. For a reporting interval of 5 minutes you would use TIME00030#000000
  • DISXXX#000000 where XXX is the distance reporting interval desired in meters. Use 0 to disable distance reporting.

CT02 SMS Setup

The CT02can be setup to report to the portal using the following SMS commands (note the default password of 000000 is used in the examples below):

  • W000000,010,{SIM #}
  • W000000,011,{APN},{APN Username},{APN Password}
  • W000000,012,66.165.183.84,4786
  • W000000,013,1
  • W000000,014,XXXXX where XXXXX is the reporting interval desired in increments of 10 seconds, with 0 to disable. For a reporting interval of 5 minutes you would use W000000,014,00030.
  • W000000,036,X where X is the degree reporting interval desired. Use 0 to disable heading-change reporting.
  • W000000,045,X where X is the distance reporting interval desired in meters. Use 0 to disable distance reporting.